Metering Solutions - All types of meter... for all applications
 

energy meters

Energy Meters

Metering Solutions supply energy/heat meters for heating, cooling and solar applications to the UK Markets that are designed for industrial/commercial and domestic applications.  The comprehensive range of energy meters are approved to EN 1434 and MID class 2 ; these approvals guarantees conformance to installation, operating monitoring and maintenance and also allows these to be utilsed for the RHI scheme.

What is the RHI Scheme?

On 10 March 2011, the Government announced the details of the Renewable Heat Incentive policy to revolutionise the way heat is generated and used. This is the first financial support scheme for renewable heat of its kind in the world.

At a time when we can see many problems with relying on a rapidly changing world and continuous reliance on oil and gas, we are proposing to put in place a key foundation stone of our energy future where both carbon reduction and energy security are assured.

The Renewable Heat Incentive(RHI) policy document, sets out the detailed arrangements for this scheme, which will provide long-term financial support to renewable heat installations to encourage the uptake of renewable heat.

RHI scheme payments on renewable heat are based on heat metering however there are strict guidelines on the type of metering equipment utilised with the minimum approval requirement of MID class 2 (MI-004); the RAY Heat Meter & SHARKY Heat Meter comply.

More details are available using the following link DECC

To discuss your flow metering application for the RHI scheme further please do not hesitate in contacting us on 01942 722677 or e-mail sales@meteringsolutions.co.uk; alternatively please feel free to browse the information and data sheets below.

 

   

Mechanical Energy Meters

Fully electronic compact heat meter or compact cooling and heat meter with impeller scanning for recording energy and volume data. Highly accurate recording of all billing data in a heating circuit or a cooling / heating circuit at medium temperatures from 5°C up to 90°C.

To discuss your flow metering application further please do not hesitate in contacting us on 01942 722677 or e-mail sales@meteringsolutions.co.uk; alternatively please feel free to browse the information and data sheets below.

 

447 to 452 (RAY) Energy Meters

RAY Mechanical Energy Meter

RAY Mechanical Energy Meter - PDF File

Ray Mechanical Energy Meter is a fully electronic multi-jets compact heat energy meter or compact cooling energy meter with impeller scanning for recording energy and volume data. Ray is equipped with 2 temperature sensors and battery operated electronic energy calculator. Ray is available in heating and heating / cooling versions.

Features include:

  • Suitable for use in Heating - cooling - heating/cooling applications
  • MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h
  • Installation in any RETURN pipe position - horizontal only
  • Temperature range +5 to +90degC for heating and cooling applications
  • Electronic sensor control with monthly memory, historical memory and event memory
  • Extremely low power consumption enabling a long battery lifetime (12 years in standard use)
  • Radio option integrated
  • Modular versions for M-Bus and pulse outputs

 

   

Ultrasonic Energy Meters

Fully electronic compact or remote heat meter or cooling and heat meter with ultrasonic technology for recording energy and volume data. Highly accurate recording of all billing data in a heating circuit or a cooling / heating circuit at medium temperatures from 5°C up to 150°C.

To discuss your flow metering application further please do not hesitate in contacting us on 01942 722677 or e-mail sales@meteringsolutions.co.uk; alternatively please feel free to browse the information and data sheets below.

 

SHARKY 775 Heat Meter

SHARKY Ultrasonic 775 Energy Meter

SHARKY Ultrasonic Energy Meter 775 - PDF File

NEW SHARKY 775 Ultrasonic Heat Meter now available!

The SHARKY 775 Ultrasonic Energy Meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the measurement of the transit time. Ultrasonic technology offers many benefits : no moving parts (avoids wear and tear of the metering components), low pressure loss, large metering dynamics and low start flow rate, insensitiveness to suspended particles...

Features include:

  • Suitable for use in Heating - cooling - heating/cooling applications
  • MID (DE-10-MI004-PTB013) and PTB K7.2 (cooling)
  • Installation in any RETURN pipe position - horizontal, vertical or titled
  • Complete range from ND 15 mm qp 1.5 m³/h up to ND 100 mm qp 60 m³/h
  • Temperature range +5 to +130/150degC for heating application or +5 to +105degC for cooling application
  • Electronic sensor control with monthly memory, historical memory and event memory
  • Extremely low power consumption enabling a long battery lifetime (16 years in standard use)
  • 24Vac or 230Vac supply option available
  • Radio option integrated
  • Modular versions for M-Bus, RS232, RS485, Analog outputs 4-20mA, pulse outputs and pulse inputs

 

sharky fs 473

SHARKY Ultrasonic FS 473 Flow Sensor

SHARKY Ultrasonic FS 473 - PDF File

The SHARKY FS Ultrasonic Flow Sensor can be used for flow measuring in local and district heating / cooling systems. The measurement principle is static and based on the measurement of the transit time. Ultrasonic technology offers many benefits : no moving parts (avoids wear and tear of the metering components), low pressure loss, large metering dynamics, low start flowrate, insensitiveness to suspended particles...

Features include:

  • Suitable for use in Heating - cooling - heating/cooling applications
  • EN1434 class 2: q p 0.6 ... 6m³/h; MID: q p 0.6 ... 60m³/h
  • Installation in any RETURN pipe position - horizontal, vertical or titled
  • 1st approval in Europe for ultrasonic flow sensor with a dynamic range of 1:250 (q i :q p )
  • Complete range from ND 15 mm qp 1.5 m³/h up to ND 100 mm qp 60 m³/h
  • Temperature range +5 to +90degC or +5 to +105degC
  • Blind unit with extreme low power consumption enabling a long battery lifetime (12 years in standard use)
  • Open Collector pulse output or output for testing and communication
  • This can be linked to the SCYLAR INT 8 Energy Calculator

 

scylar int8 energy calculator

SCYLAR INT 8 Energy Calculator

SCYLAR INT 8 Energy Calculator - PDF File

Energy calculator for universal use in systems for heating and cooling measuring. Highly accurate recording of all billing data in local and district heating / cooling systems.

Features include:

  • Can be used for heating, cooling or combined heating / cooling
  • Approved according MID
  • Suitable for 2 and 4 wire temperature sensor connection
  • Individual remote reading (AMR) with add on modules Plug & Play
  • Optional with integrated radio, Real Data or Open Metering Standard (868 or 434 MHz)
  • 2 Communication ports (e. g. M-Bus + Radio)
  • RS485 Interface
  • 2 passive analogue outputs for 4 ... 20mA
  • Extremely low power consumption enabling a long battery lifetime (11 years in standard use)
  • 24Vac or 230Vac supply option available

 

SHARKY/MIMAS Energy Meter

SHARKY Solar Meter

SHARKY Solar - PDF File

The ultrasonic compact energy meter SHARKY Solar can be used for measuring the energy consumption in solar systems. SHARKY SOLAR is now available in nominal sizes qp0, 6 / 1.5 / 2.5 for the glycol medium TYFOCOR LS. This medium is widely used in Europe in solar systems. Often the temperatures in such systems are above 100 ° C. Therefore mechanical meters will soon reach their thermal limits. The SHARKY Solar can be use continuous at 130 ° C as a precise measuring system.

Features include electronic sensor control for recording flow rate, power by lithium battery with approximate lifetime of 16 years, 24Vac or 230Vac, insensitive against dirt, no calming sections necessary in the inlet or outlet (standard installation), high long term stability (verified with independent AGFW test).

This model can be equipped with a pulse output (reedswitch), M-BUS output linking to remote monitoring equipment (i.e. counters, AMR systems. BMS (building management systems) or alternatively radio module for AMR system. Available in sizes from 1/2" & 3/4" for installation in horizontal or vertical pipes.

 

   

Superseded Flowmeters

The following are the items which have been superseded which provides full details of their operation complete with data sheet but also provides links to receommended alternative options.

SHARKY/MIMAS Energy Meter

SHARKY Ultrasonic 773 Energy Meter

SHARKY Ultrasonic Energy Meter 773 - PDF File

Please note this data sheet and information is provided for the older style flowmeters - this has been superseded by the SHARKY Ultrasonic Energy Meter 775

The SHARKY Ultrasonic Heat Meter can be used for accurate recording of all billing data in a heating circuit or a cooling / heating circuit as these are EN1434 approved; also the first to receive approval in Europe for ultrasonic meter with dynamic range of 1:250 in class 2.

Features include electronic sensor control for recording flow rate, power by lithium battery with approximate lifetime of 16 years, 24Vac or 230Vac, insensitive against dirt, no calming sections necessary in the inlet or outlet (standard installation), high long term stability (verified with independent AGFW test).

This model can be equipped with a pulse output (reedswitch), M-BUS output linking to remote monitoring equipment (i.e. counters, AMR systems. BMS (building management systems) or alternatively radio module for AMR system. Available in sizes from 1/2" to 4" for installation in horizontal or vertical pipes.

 

energy int6 energy calculator

ENERGY INT 6 Energy Calculator

ENERGY INT 6 Energy Calculator - PDF File

Please note this data sheet and information is provided for the older style calculators - this has been superseded by the SCYLAR INT 8 Energy Calculator

Energy calculator for universal use in systems for heating and cooling measuring. Highly accurate recording of all billing data in local and district heating / cooling systems.

Features include:

  • Can be used for heating, cooling or combined heating / cooling
  • Meets the requirements of EN 1434
  • Suitable for 2 and 4 wire temperature sensor connection
  • Programmable history memory (daily, weekly, monthly)
  • Individual remote reading (AMR) with add on modules Plug & Play
  • Optional with integrated radio, Real Data or Open Metering Standard (868 or 434 MHz)
  • 2 Communication ports (e. g. M-Bus + Radio)
  • RS485 Interface
  • 2 passive analogue outputs for 4 ... 20mA
  • Extremely low power consumption enabling a long battery lifetime (12 years in standard use)
  • 24Vac or 230Vac supply option available

 

Homepage | Contact | Water Meters | Energy Meters |Turbine Flow Meters | Electromagnetic Flow Meters | Oil / Fuel / Flow Meters | Chemical Flow Meters | Flow Monitors | Gas Meters | Batch Systems | Counters | | Accessories